H03VV-F copper wire flexible wire building wire house wire
1.Application:
These cables are used for general wiring, unenclosed, enclosed in conduit, buried direct or in underground ducts for domestic, commercial and industrial aaplications where not subject to mechanical damage.
2.Standard:
GB/T 5023-2008, BS 6004, IEC 60227, VDE ,UL
3.Specification:
Reference No 6192y
Flat Twin
Notes
1.Conductor of high conductivity copper wires insulated with PVC compound.sheathed with PVC compound
2.Color of sheath:gray or white,
450/750V PVC Insulated (Non-Sheathed) Flexible Conductor General Purpose Cables to BS 6004
Single Core PVC Insulated
Notes
1.Conductor of high conductivity copper wires insulated with PVC compound.
2.Colors of standard:red, black, brown, gray,orange, white, violet, pink,green/yellow, yellow
Size of conductor | Nominal thickness of insulation mm | Mean overall diameter Upper limit mm | renmincable.en.made-in-china.com weight per km kg | |
Nominal cross-sectional area mm2 | Number and diameter of wires no./mm | |||
1.0 | 32/0.20 | 0.6 | 3.0 | 16 |
1.5 | 30/0.25 | 0.7 | 3.5 | 21 |
2.5 | 50/0.25 | 0.8 | 4.2 | 33 |
4 | 56/0.30 | 0.8 | 4.8 | 50 |
6 | 84/0.30 | 0.8 | 6.3 | 70 |
10 | 80/0.40 | 1.0 | 7.6 | 120 |
16 | 126/0.40 | 1.0 | 8.8 | 175 |
25 | 196/0.40 | 1.2 | 11.0 | 290 |
35 | 276/0.40 | 1.2 | 12.5 | 400 |
50 | 396/0.40 | 1.4 | 14.5 | 565 |
70 | 360/0.50 | 1.4 | 17.0 | 770 |
95 | 475/0.50 | 1.6 | 19.0 | 1010 |
120 | 608/0.50 | 1.6 | 21.0 | 1260 |
150 | 756/0.50 | 1.8 | 23.5 | 1580 |
185 | 925/0.50 | 2.0 | 26.0 | 1900 |
240 | 1221/0.50 | 2.2 | 29.5 | 2500 |
Size of conductor | Nominal thickness of insulation mm | Mean overall dimensions | Approx. net weight per km kg | ||
Nominal cross-sectional area mm2 | Number and diameter of wires no/mm | Lower Limit mm | Upper Limit Mm | ||
0.5 | 28/0.15 | 0.8 | 2.5x5.0 | 3.0x6.0 | 24 |
0.75 | 42/0.15 | 0.8 | 2.7x5.4 | 3.2x6.4 | 29 |
Size of conductor | Nominal thickness of insulation mm | Mean overall diameter Upper limit mm | Approx. net weight per km kg | |
Nominal cross-sectional area mm2 | Number and diameter of wire no/mm | |||
0.5 | 16/0.20 | 0.6 | 2.6 | 10 |
0.75 | 24/0.20 | 0.6 | 2.8 | 13 |
1.0 | 32/0.20 | 0.6 | 3.0 | 16 |
1.5* | 30/0.25 | 0.7 | 3.5 | 20 |
2.5* | 50/0.25 | 0.8 | 4.2 | 32 |
4.0* | 56/0.30 | 0.8 | 4.8 | 49 |
Size of conductor | Nominal thickness of insulation mm | Nominal thickness of sheath mm | Mean overall dimensions | Approx. net weight per km kg | ||
Nominal cross- sectional area mm2 | Number and diameter of wires No./mm | Upper Limit mm | Upper Limit mm | |||
0.5 | 16/0.20 | 0.5 | 0.6 | 3.0x4.8 | 3.6x6.0 | 27 |
0.75 | 24/0.20 | 0.5 | 0.6 | 3.2x5.2 | 3.9x6.4 | 34 |
Size of conductor | Nominal thickness of insulation mm | Nominal thickness of sheath mm | Mean overall dimensions | Approx. net weight per km kg | ||
Nominal cross- sectional area mm2 | Number and diameter of wires No./mm | Upper Limit mm | Upper Limit mm | |||
0.5 | 16/0.20 | 0.5 | 0.6 | 4.8 | 6.0 | 36 |
0.75 | 24/0.20 | 0.5 | 0.6 | 5.2 | 6.4 | 45 |
Size of conductor | Nominal thickness of insulation mm | Nominal thickness of Sheath mm | Mean overall dimensions | Approx. net weight per km kg | ||
Nominal cross- sectional area mm2 | Number and diameter of wires no/mm | Lower Limit mm | Upper Limit mm | |||
0.5 | 16/0.2 | 0.5 | 0.6 | 5.0 | 6.2 | 44 |
0.75 | 24/0.2 | 0.5 | 0.6 | 5.4 | 6.8 | 55 |
Size of conductor | Nominal thickness of insulation mm | Nominal thickness of sheath mm | Mean overall dimensions | Approx. net weight per km kg | ||
Nominal cross- sectional area mm2 | Number and diameter of wires no/mm | Lower Limit mm | Upper Limit mm | |||
0.75 | 24/0.20 | 0.6 | 0.8 | 6.0 | 7.6 | 63 |
1.0 | 32/0.20 | 0.6 | 0.8 | 6.4 | 8.0 | 73 |
1.25 | 40/0.20 | 0.7 | 0.8 | 7.0 | 8.6 | 84 |
1.5 | 30/0.25 | 0.7 | 0.8 | 7.4 | 9.0 | 95 |
2.5 | 50/0.25 | 0.8 | 1.0 | 8.9 | 11.0 | 145 |
Size of conductor | Nominal thickness of insulation mm | Nominal thickness of sheath mm | Mean overall dimensions | Approx. net weight per km kg | ||
Nominal cross- sectional area mm2 | Number and diameter of wires no/mm | Lower limit mm | Upper limit mm | |||
0.75 | 24/0.20 | 0.6 | 0.8 | 6.8 | 8.6 | 78 |
1.0 | 32/0.20 | 0.6 | 0.9 | 7.6 | 9.4 | 110 |
1. 5 | 30/0.25 | 0.7 | 1.0 | 9.0 | 11.0 | 150 |
2.5 | 50/0.25 | 0.8 | 1.1 | 10.5 | 13.0 | 220 |
4.Packing in plastic reel, paper reel ,wooden drum or as customer's requirement.
5.Our factory:
People's Cable Group Co., Ltd. was founded in 2007, located in Zhengzhou Gongyi economic development zone. Our company has 2 factories (Zhitian factory and Zhulin factory), occupies total area of more than 300,000 square meters, with building area 230,000 square meters.
6.Certificate:
As first rank of the cable supplier in China, we have obtained CCC, ISO9001, ISO14001, OHSAS certificates, passed the SGS and BV test, and our brand "RMJT" be given China famous brand.
7.Customer Visit:
We have a professional sales team with each of them has engaged in this job for 3-10 years, so that we can provide the comprehensive and professional technology for you. With the perfect quality and after sales service, till now we have exported to more than 80 countries, welcome to visit us and establish win-win establish relationship!
8.Contact:
Dear friends, welcome to our store. We will provide you with china wholesale market market products, excellent service and reasonable price.Please contact us if have any questions about the product. we will answer the questions carefully.At last,I wish you a pleasant purchase.
Factrory ADD:No.13th,YongDing Road, Goingyi,Zhengzhou city, Henan province, China.